YXE VALVE ISLAND WITH PROFIBUS-DP : The YXE Island is designed to overcome the lengthy wiring. It is easy to operate, maintain and control. Solenoid Valves Island is configured to exchange data through field bus using PROFIBUS-DP protocol. The field bus connectivity is achieved by using Rs. 485 interface.
COMMUNICATION CHARACTERISTIC :
| Protocol | PROFIBUS-DP, DIN 19245-part 3-EN 50170. | | Transmission | Shielded and twisted pair. | | FIELDBUS Structure | Line or tree using repeaters. | | Max. No. of solenoid valves | 63 | | Max. No. of valves per island | 16 | | FIELDBUS cable length | 1200 m at 9.6 kbps and 100 m at 12 Mbps. | | Island addressing | Rotary switch on the board |
ELECTRICAL CHARACTERISTIC : | Supply Voltage | 24V DC + 10% with maximum 15% ripple. | | FIELDBUS consumption | < 150 mA | | Solenoid consumption | 1.2 W | | Protection | IP55 | | Supply connection (24 V) | M8 socket 4 pin male | | FIELDBUS connection | IN 5 pin M12 - B male. OUT 5 pin M12 - B male | | Earthing | Onthe valve island | | Electromagnetic compatibility | CE, directive EMC 89/336/EEC. | PNEUMATIC ELEMENTS : All the options are available as specified. All the pressure ranges are applicable as specified. It is recommended to use all the parts as specified by ROTEX. All the valve islands are supplied duly tested for FIELDBUS. Kindly specify the special characteristics as required.
PROFIBUS-DP connection : The right side of the YXE valve island as viewed from top will be as shown. The valve island is provided with two M 12 connectors for communication and one M8 connector for power supply.
Certification :
|